POLIBRID® 670S is a solventless two component, organo-silane modified, amido-amine epoxy primer designed specifically for applications of POLIBRID solventless elastomeric polyurethane coatings and linings to carbon steel or concrete substrates.

 

POLIBRID 670S utilizes the most advanced technology in moisture-tolerant, flexible epoxy resins, producing tenacious adhesion to the substrate while creating a strong chemical bond to the Polibrid elastomers. Its superior moisture tolerance serves as a barrier to substrate moisture that allows application of the POLIBRID elastomeric polyurethane coating and lining materials over dry or damp concrete surfaces. The use of this primer to damp or wet metallic surfaces is not recommended. 

POLIBRID 670S is topcoated with the POLIBRID elastomers after it sets up firm, but while still in a tacky condition, using "wet-to-wet" application techniques that enhance adhesion and increase productivity. POLIBRID 670S does not contain  tars, lead, zinc or chromates and complies with all known VOC emissions standards.

POLIBRID 670S is highly recommended for application to concrete substrates, especially damp surfaces such as those found in pump stations, manholes, cooling tower basins, secondary containment installations and other below-grade or at-grade structures. It is also recommended for application to metallic substrates when surface profile requirements for application of the POLIBRID elastomers direct to metal cannot be achieved. Call your regional technical service representative for specific recommendations.

Top of Page

Generic Type Modified Amido-Amine Epoxy
Color Turquoise
Solids Content 99% Minimum
VOC Content Theoretical: 0.028 lbs./gal. (3.3 gm./lt.)
Components Two
Mix Ratio By Volume 1A:1B (1 Part "A" to 1 Part "B")
Recommended Thickness 5 mils DFT (125µ)
Theoretic Coverage 1,599 sq.ft./gal. @ 1 mil (39.8 m²/lt. @ 25µ)
320 sq.ft./gal. @ 5 mils (16.7 m²/lt. @ 125µ)
Drying Time ± 48 hours @ 60°F(16°C)
± 32 hours @ 72°F(22°C)
± 12 hours @ 90°F(32°C)
Flexibility Passes multiple bends on 1/4" to 3/16" conical mandrel
Hardness "2H" in 7 Days @ 72°F(22°C)
Relative Humidity Maximum: 95%
Ambient Temperature Minimum: 60°F(16°C) ~ Optimum: 75°F(24°C)
Substrate Temperature Minimum: 55°F(13°C) and at least 5°F(3°C) above Dew Point
Optimum: 75°F(24°C)
Materials Temperature 60°F to 90°F(16°C to 32°C)

IMPORTANT LIMITATION: Not recommended for application to wet surfaces. This product alone is not waterproofing. Concrete may to be primed may be damp to the touch but MUST be free of condensation and surface moisture. This product will neither repair leaks nor will it remedy excessive hydrostatic conditions! 

Top of Page

AIRLESS SPRAY (Preferred Method) 

Pump 30:1 Fluid-to-Air Ratio
Hose Diameter 3/8"
Spray Tips GRACO® R-A-C III or IV
Tip Apertures 0.017" to 0.021"
Fluid Pressure > 2,500 psi

CONVENTIONAL SPRAY

Pump Spray Pot with Dual Regulators
Air Supply 100 psi
Hose Diameter 1/2"
Hose Length (Max.) 50 Ft.
Air Hose Diameter 5/16"
Fluid Pressure 10-25 psi
Atomization Pressure 50-75 psi

ROLLER

Use roller suitable for solvent base materials. Nap length will depend on the roughness of the substrate.

BRUSH

Distribute evenly using full brush strokes.

Top of Page

Recoat Window For optimum results, topcoat before fully dried to the touch. Primer must be free of dust, moisture, condensation and contaminants before topcoating. If primer dries hard to the touch before topcoating, application of an additional coat of primer is recommended.
Mixing Before using, agitate both components in their original containers for 5 minutes to produce complete suspension. Measure components at precise 1A:1B volume ratio, pour into clean separate container and blend by agitating mixed components for 5 additional minutes. Do not apply primer that has exceeded its usable pot life.
Pot Life - (Assuming 2 gallons of mixed material at 72°F(22°C). Pot life is reduced at higher temperatures or when mixing larger volumes.) ± 2 hours @ 60°F(16°C)
± 1 hour @ 72°F(22°C)
± 30 minutes @ 90°F(32°C)
Thinning Not Recommended
Cleaning Solvents MEK, Toluene
Flash Point (EPA 1010) Part A: >205°F(96°C) ~ Part B: 205°F(96°C)
Packaging (Kit) 1 Gallon Cans or 5 Gallon Pails
Sales Units 2 Gal. or 10 Gal. Kits
Weight per Gallon 11.2 lbs./gal. (Mixed)
Storage Keep in a cool, dry place. Do not store directly over concrete or earth. Avoid freezing. Do not open until ready to use.
Shelf Life 1 Year (Stored dry, in original unopened containers)

Top of Page

Allow a minimum 28 day cure period for new Portland Cement ASTM Type 1 concrete. Decontaminate per ASTM D-4258. Abrasive blast clean per ASTM D-4259 to remove laitance, loose concrete, existing coatings, and to produce surface profile resembling coarse sandpaper. Waterblasting alone or acid etching are not acceptable. Repair all leaks as directed by Engineer and eliminate standing water. If necessary, resurface with high-strength, rapid-curing, zero-shrinkage resurfacing product, before primer application. Concrete must be free of dust and contaminants prior to primer application.

Top of Page

Health & Safety

AVOID SKIN CONTACT! Wear chemical goggles as minimum eye protection, use impermeable gloves and cover all exposed skin. Do not allow contaminated clothing to contact skin. Use properly fitted organic vapor respirators and adequate ventilation. Wash hands before eating, smoking or using washroom. Follow precautions in CFR Title 29 (OSHA) and all pertinent local, state & federal health, safety and environmental regulations. Read, understand and fully comply with recommendations made in Material Safety Data Sheets (MSDS) supplied for individual coating components!

Confined Spaces

COMPLY WITH PERTINENT OSHA REGULATIONS RELATIVE TO WORK IN CONFINED SPACES! Provide forced air ventilation. Workers must use carbon monoxide filtered breathing air-line respirators. If flammable vapors are present, use only non-sparking tools and equipment.

First Aid

SKIN CONTACT: Wash thoroughly with plenty of soap and water.

EYE CONTACT: Immediately flush with fresh clean water for at least fifteen (15) minutes and get specialized medical attention promptly.

INHALATION: Remove to fresh air and provide oxygen.

INGESTION: Immediately call a physician or poison control center. DO NOT INDUCE VOMITING!

THESE MATERIALS ARE FOR INDUSTRIAL USE BY FACTORY-TRAINED QUALIFIED TECHNICIANS ONLY! CONSULT YOUR POLIBRID TECHNICAL SERVICE REPRESENTATIVE BEFORE SPECIFYING!

LIMITATIONS & IMPORTANT NOTES: This data sheet contains information accurate to the best of our knowledge at time of printing. Such data may be incomplete and subject to varying interpretations, however, and must be considered as general guidelines only. Compliance with project specifications, actual job conditions, and the buyer's specific needs must be considered by the specifier. We do not guarantee the results to be obtained by others unless specifically done so, in writing, by an authorized officer of Polibrid Coatings, Inc. Since methods and conditions of application are beyond our control, buyer assumes all risk of use or handling. NO WARRANTY, EXPRESS OR IMPLIED IS MADE CONCERNING THE USE OF THESE PRODUCTS OR RECOMMENDATIONS AND NO LIABILITY FOR THEIR USE, OR INABILITY TO USE, IS ACCEPTED. The manufacturer's sole responsibility for claims arising out of breach of warranty, negligence, strict liability or otherwise, is limited to the purchase price and/or replacement of the materials supplied by Polibrid Coatings, Inc., who reserves the right to modify this data without previous notice or liability. 

© Copyright 2004 Polibrid Coatings, Inc. All rights reserved. ® "Polibrid" is a Registered Trademark of Polibrid Coatings, Inc. of Brownsville, Texas. All other logos & trademarks are the property of their respective owners. Contact marketing@polibrid.com for comments or suggestions on this website.
Last revised: January 18, 2005

Top of Page

Click here to open PDF version of this file!